Product Overview

Category

PR11-2-12.5A-25044-6-V belongs to the category of electrical components and is specifically a power relay.

Use

This product is used for switching high-power electrical circuits in various applications, such as industrial machinery, automotive systems, and household appliances.

Characteristics

  • Voltage Rating: 250V
  • Current Rating: 12.5A
  • Configuration: SPDT (Single Pole Double Throw)
  • Package Type: Enclosed in a protective casing
  • Essence: Reliable and durable switching capability
  • Packaging/Quantity: Typically packaged individually or in small quantities for distribution and sale

Specifications

The PR11-2-12.5A-25044-6-V has the following specifications: - Contact Form: 1 Form C (SPDT) - Coil Voltage: 12V DC - Contact Material: Silver alloy - Operate Time: 10ms max - Release Time: 5ms max - Insulation Resistance: 1000MΩ min at 500VDC - Dielectric Strength: Between open contacts: 750VAC, between coil and contacts: 1500VAC

Detailed Pin Configuration

The pin configuration of PR11-2-12.5A-25044-6-V is as follows: - Pin 1: Coil+ - Pin 2: Coil- - Pin 3: Common - Pin 4: Normally Open (NO) - Pin 5: Normally Closed (NC)

Functional Features

  • High current-carrying capacity
  • Low power consumption
  • Compact design for space-saving installation
  • Suitable for both AC and DC applications
  • Reliable switching performance over a long operational lifespan

Advantages and Disadvantages

Advantages

  • Robust construction for reliable operation in harsh environments
  • Versatile application across different industries
  • Low coil power consumption
  • Wide operating temperature range

Disadvantages

  • Relatively higher cost compared to standard relays
  • Sensitive to voltage spikes and transients

Working Principles

PR11-2-12.5A-25044-6-V operates on the principle of electromagnetic induction. When the coil is energized, it generates a magnetic field that attracts the armature, causing the contacts to change position and complete or interrupt the circuit.

Detailed Application Field Plans

This power relay is commonly used in: - Industrial control systems - Automotive electronics - HVAC (Heating, Ventilation, and Air Conditioning) equipment - Home appliances such as washing machines and refrigerators

Detailed and Complete Alternative Models

Some alternative models to PR11-2-12.5A-25044-6-V include: - PR11-2-10A-25022-6-V - PR11-2-15A-25066-6-V - PR11-2-20A-25088-6-V

In conclusion, PR11-2-12.5A-25044-6-V is a versatile and reliable power relay with a wide range of applications across various industries, offering efficient switching capabilities and durability.

[Word count: 456]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací PR11-2-12.5A-25044-6-V v technických řešeních

  1. What is PR11-2-12.5A-25044-6-V?

    • PR11-2-12.5A-25044-6-V is a specific type of relay used in electrical and electronic systems to control the flow of electricity.
  2. What are the key specifications of PR11-2-12.5A-25044-6-V?

    • The PR11-2-12.5A-25044-6-V relay has a 12.5A current rating, a 250VAC voltage rating, and a 44-6 coil voltage specification.
  3. How is PR11-2-12.5A-25044-6-V typically used in technical solutions?

    • PR11-2-12.5A-25044-6-V is commonly used in applications such as industrial control systems, automation equipment, and power distribution systems to switch high-power electrical loads.
  4. What are the common wiring configurations for PR11-2-12.5A-25044-6-V?

    • The PR11-2-12.5A-25044-6-V relay can be wired in various configurations including normally open (NO), normally closed (NC), and changeover (CO) depending on the specific application requirements.
  5. Are there any special considerations for mounting PR11-2-12.5A-25044-6-V in a technical solution?

    • It's important to ensure proper ventilation and adequate clearance around the relay to prevent overheating and to follow the manufacturer's guidelines for mounting and installation.
  6. What are the typical failure modes of PR11-2-12.5A-25044-6-V and how can they be mitigated?

    • Common failure modes include contact welding and coil burnout. Mitigation strategies may involve using appropriate protective circuitry and regular maintenance checks.
  7. Can PR11-2-12.5A-25044-6-V be used in high-frequency switching applications?

    • PR11-2-12.5A-25044-6-V may not be suitable for high-frequency switching due to its mechanical limitations, and alternative solid-state relays may be more appropriate for such applications.
  8. What are the environmental considerations for using PR11-2-12.5A-25044-6-V in technical solutions?

    • PR11-2-12.5A-25044-6-V should be used within specified temperature and humidity ranges, and protection from dust, moisture, and other contaminants should be considered.
  9. Are there any recommended testing procedures for verifying the functionality of PR11-2-12.5A-25044-6-V in a technical solution?

    • Testing procedures may include continuity checks, insulation resistance tests, and load capacity verification to ensure proper operation.
  10. Where can I find detailed technical documentation and support for PR11-2-12.5A-25044-6-V?

    • Detailed technical documentation and support for PR11-2-12.5A-25044-6-V can typically be obtained from the manufacturer's website, authorized distributors, or technical support channels.