Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-15-S-L-M12-20MA-000-000

P51-15-S-L-M12-20MA-000-000

Product Overview

Category

The P51-15-S-L-M12-20MA-000-000 belongs to the category of industrial sensors.

Use

It is used for measuring and monitoring various parameters in industrial processes, such as pressure, temperature, or flow.

Characteristics

  • High precision and accuracy
  • Robust construction for industrial environments
  • Compatibility with M12 connectors
  • Wide operating range
  • Easy integration into existing systems

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage. The package includes the sensor unit, necessary cables, and documentation.

Essence

The essence of the P51-15-S-L-M12-20MA-000-000 lies in its ability to provide reliable and accurate data for industrial process control and automation.

Packaging/Quantity

The standard packaging includes one P51-15-S-L-M12-20MA-000-000 sensor unit. However, bulk quantities may be available for larger industrial applications.

Specifications

  • Model: P51-15-S-L-M12-20MA-000-000
  • Output: 4-20mA
  • Pressure Range: 0-100 psi
  • Operating Temperature: -40°C to 125°C
  • Material: Stainless steel
  • Protection Rating: IP67
  • Connector Type: M12

Detailed Pin Configuration

The detailed pin configuration of the P51-15-S-L-M12-20MA-000-000 sensor can be found in the product datasheet provided by the manufacturer.

Functional Features

  • High-precision pressure sensing
  • Compatibility with standard M12 connectors
  • Robust construction for harsh industrial environments
  • Linear output signal for easy integration with control systems
  • Wide operating temperature range

Advantages and Disadvantages

Advantages

  • High accuracy and reliability
  • Robust construction for durability
  • Easy integration into existing systems
  • Wide operating temperature range

Disadvantages

  • Limited pressure range compared to some other industrial sensors
  • May require specific connector types for integration

Working Principles

The P51-15-S-L-M12-20MA-000-000 operates on the principle of converting pressure variations into electrical signals. These signals are then processed to provide accurate pressure readings for industrial applications.

Detailed Application Field Plans

The P51-15-S-L-M12-20MA-000-000 sensor is suitable for various industrial applications, including: - Hydraulic systems - Pneumatic systems - Industrial machinery - Process control and automation - HVAC systems

Detailed and Complete Alternative Models

  1. P51-15-S-L-M12-10MA-000-000
  2. P51-15-S-L-M12-4-20MA-000-000
  3. P51-15-S-L-M12-0-5V-000-000
  4. P51-15-S-L-M12-1-5V-000-000

These alternative models offer similar functionality with variations in output signals and pressure ranges to suit different industrial requirements.

This comprehensive entry provides an in-depth understanding of the P51-15-S-L-M12-20MA-000-000 sensor, covering its basic information, specifications, functional features, advantages and disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-15-S-L-M12-20MA-000-000 v technických řešeních

  1. What is the P51-15-S-L-M12-20MA-000-000 used for?

    • The P51-15-S-L-M12-20MA-000-000 is a pressure sensor commonly used in industrial and technical applications to measure and monitor pressure levels.
  2. What is the operating voltage of the P51-15-S-L-M12-20MA-000-000?

    • The operating voltage of the P51-15-S-L-M12-20MA-000-000 is typically 10-30V DC.
  3. What is the output signal of the P51-15-S-L-M12-20MA-000-000?

    • The P51-15-S-L-M12-20MA-000-000 provides a 4-20mA output signal, which is commonly used for transmitting sensor data over long distances without signal degradation.
  4. What is the pressure range that the P51-15-S-L-M12-20MA-000-000 can measure?

    • The P51-15-S-L-M12-20MA-000-000 is available in various pressure ranges, but a common range is 0-100 psi.
  5. Is the P51-15-S-L-M12-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-15-S-L-M12-20MA-000-000 is designed to withstand harsh industrial environments and is often rated for high levels of shock and vibration resistance.
  6. Can the P51-15-S-L-M12-20MA-000-000 be used for measuring liquid pressure?

    • Yes, the P51-15-S-L-M12-20MA-000-000 can be used for measuring pressure in both gas and liquid applications, depending on the specific model and configuration.
  7. What is the accuracy of the P51-15-S-L-M12-20MA-000-000?

    • The accuracy of the P51-15-S-L-M12-20MA-000-000 is typically within ±0.5% of full scale, providing reliable and precise pressure measurements.
  8. Does the P51-15-S-L-M12-20MA-000-000 require calibration?

    • Yes, like most pressure sensors, the P51-15-S-L-M12-20MA-000-000 should be calibrated periodically to ensure accurate readings.
  9. Can the P51-15-S-L-M12-20MA-000-000 be integrated with PLC systems?

    • Yes, the 4-20mA output signal of the P51-15-S-L-M12-20MA-000-000 makes it compatible with many programmable logic controller (PLC) systems commonly used in industrial automation.
  10. Is the P51-15-S-L-M12-20MA-000-000 suitable for use in hazardous areas?

    • Some models of the P51-15-S-L-M12-20MA-000-000 are designed to meet hazardous area certifications, making them suitable for use in potentially explosive atmospheres.