Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-3000-S-AA-I12-20MA-000-000

P51-3000-S-AA-I12-20MA-000-000

Product Overview

Category

The P51-3000-S-AA-I12-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial processes

Package

The product is typically packaged in a protective casing to ensure durability during transportation and storage.

Essence

The essence of the P51-3000-S-AA-I12-20MA-000-000 lies in its ability to accurately measure and transmit pressure data in industrial settings.

Packaging/Quantity

The standard packaging includes one unit of the pressure transmitter.

Specifications

  • Pressure Range: 0-3000 psi
  • Output Signal: 4-20 mA
  • Accuracy: ±0.5%
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel

Detailed Pin Configuration

The detailed pin configuration of the P51-3000-S-AA-I12-20MA-000-000 includes input power, output signal, and ground pins, ensuring seamless integration into industrial control systems.

Functional Features

  • High precision pressure measurement
  • Compatibility with various industrial fluids
  • Long-term stability
  • Overpressure protection

Advantages and Disadvantages

Advantages

  • Reliable and accurate pressure measurement
  • Robust construction for harsh industrial environments
  • Wide operating temperature range

Disadvantages

  • Higher initial cost compared to some alternatives
  • May require periodic calibration

Working Principles

The P51-3000-S-AA-I12-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted to a control system for monitoring and control purposes.

Detailed Application Field Plans

The P51-3000-S-AA-I12-20MA-000-000 is suitable for a wide range of industrial applications, including: - Hydraulic systems - Process control - Manufacturing equipment - Industrial machinery

Detailed and Complete Alternative Models

  • Model A: P51-2000-S-AA-I12-20MA-000-000
  • Model B: P51-5000-S-AA-I12-20MA-000-000
  • Model C: P51-3000-S-AB-I12-20MA-000-000

This completes the entry for the P51-3000-S-AA-I12-20MA-000-000, providing comprehensive information about its category, use, characteristics, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-3000-S-AA-I12-20MA-000-000 v technických řešeních

  1. What is the application of P51-3000-S-AA-I12-20MA-000-000?

    • The P51-3000-S-AA-I12-20MA-000-000 is a pressure transducer commonly used in industrial and technical applications to measure and monitor pressure levels.
  2. How does P51-3000-S-AA-I12-20MA-000-000 work?

    • This pressure transducer works by converting the applied pressure into an electrical signal, typically a 4-20mA current loop signal, which can be easily interpreted by control systems or data acquisition equipment.
  3. What are the typical industries that use P51-3000-S-AA-I12-20MA-000-000?

    • Industries such as oil and gas, automotive, aerospace, manufacturing, and HVAC commonly utilize the P51-3000-S-AA-I12-20MA-000-000 for pressure monitoring and control.
  4. Can P51-3000-S-AA-I12-20MA-000-000 be used in harsh environments?

    • Yes, this pressure transducer is designed to withstand harsh environmental conditions and is often used in applications where exposure to extreme temperatures, vibration, or corrosive substances is a concern.
  5. What is the accuracy of P51-3000-S-AA-I12-20MA-000-000?

    • The P51-3000-S-AA-I12-20MA-000-000 typically offers high accuracy, often within a few percentage points of the measured pressure range.
  6. Is P51-3000-S-AA-I12-20MA-000-000 compatible with different pressure ranges?

    • Yes, this pressure transducer can be configured to measure various pressure ranges, making it versatile for different technical solutions.
  7. How do I install and calibrate P51-3000-S-AA-I12-20MA-000-000?

    • Installation and calibration procedures may vary, but typically involve mounting the transducer, connecting the electrical leads, and adjusting the output signal to match the desired pressure range.
  8. Can P51-3000-S-AA-I12-20MA-000-000 communicate with PLCs or control systems?

    • Yes, the 4-20mA output signal from the P51-3000-S-AA-I12-20MA-000-000 can be easily integrated with programmable logic controllers (PLCs) and other control systems for real-time monitoring and control.
  9. What maintenance is required for P51-3000-S-AA-I12-20MA-000-000?

    • Regular inspection for damage, cleaning of the sensing element, and verification of calibration are common maintenance tasks for ensuring the continued accuracy and reliability of the transducer.
  10. Are there any special considerations when using P51-3000-S-AA-I12-20MA-000-000 in hazardous areas?

    • When used in hazardous areas, it's important to ensure that the pressure transducer meets relevant safety standards and is properly certified for use in those environments.