Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-50-G-F-I36-20MA-000-000

P51-50-G-F-I36-20MA-000-000

Basic Information Overview

Category

The P51-50-G-F-I36-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure readings in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various media
  • Long-term stability

Package

The P51-50-G-F-I36-20MA-000-000 comes in a durable and protective packaging to ensure safe transportation and storage.

Essence

The essence of the P51-50-G-F-I36-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in challenging industrial environments.

Packaging/Quantity

The product is typically packaged individually and is available in single-unit quantities.

Specifications

  • Pressure Range: 0-50 psi
  • Output Signal: 4-20 mA
  • Accuracy: ±0.5% full scale
  • Operating Temperature: -40°C to 85°C
  • Pressure Connection: G 1/4" male
  • Electrical Connection: Integral cable

Detailed Pin Configuration

The detailed pin configuration of the P51-50-G-F-I36-20MA-000-000 includes: - Pin 1: Power supply (+) - Pin 2: Power supply (-) - Pin 3: Signal output - Pin 4: Not connected

Functional Features

  • Pressure sensing element for accurate measurements
  • Signal conditioning for linear output
  • Robust construction for durability
  • Integrated temperature compensation for reliable performance across varying temperatures

Advantages

  • High accuracy ensures precise pressure readings
  • Robust construction enables use in harsh industrial environments
  • Wide operating temperature range allows for versatile application
  • Compatibility with various media enhances its usability

Disadvantages

  • Limited to specific pressure range (0-50 psi)
  • Requires proper calibration for optimal performance

Working Principles

The P51-50-G-F-I36-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal. This is achieved through the use of a pressure sensing element that undergoes signal conditioning to provide a linear 4-20 mA output proportional to the measured pressure.

Detailed Application Field Plans

The P51-50-G-F-I36-20MA-000-000 is suitable for various industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery - HVAC systems

Detailed and Complete Alternative Models

Some alternative models to the P51-50-G-F-I36-20MA-000-000 include: - P51-100-G-F-I36-20MA-000-000 (0-100 psi range) - P51-30-G-F-I36-20MA-000-000 (0-30 psi range) - P51-50-G-F-I24-20MA-000-000 (4-20 mA output)

In conclusion, the P51-50-G-F-I36-20MA-000-000 industrial pressure transmitter offers high accuracy, robust construction, and wide compatibility, making it a valuable component in various industrial settings.

[Word count: 411]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-50-G-F-I36-20MA-000-000 v technických řešeních

  1. What is the application of P51-50-G-F-I36-20MA-000-000 in technical solutions?

    • The P51-50-G-F-I36-20MA-000-000 is a pressure transducer commonly used in various technical solutions to measure and monitor pressure in industrial processes.
  2. How does P51-50-G-F-I36-20MA-000-000 work in technical solutions?

    • This pressure transducer works by converting the applied pressure into an electrical signal, typically a 4-20mA output, which can be easily integrated into control systems for monitoring and automation.
  3. What are the typical industries that use P51-50-G-F-I36-20MA-000-000 in their technical solutions?

    • Industries such as oil and gas, automotive, aerospace, manufacturing, and HVAC commonly utilize this pressure transducer in their technical solutions.
  4. What are the key features of P51-50-G-F-I36-20MA-000-000 that make it suitable for technical solutions?

    • Some key features include its high accuracy, rugged construction, wide operating temperature range, and compatibility with various media types, making it versatile for different technical applications.
  5. Can P51-50-G-F-I36-20MA-000-000 be used in hazardous environments?

    • Yes, this pressure transducer is available in intrinsically safe and explosion-proof versions, allowing its use in hazardous environments where safety is a concern.
  6. How do I calibrate P51-50-G-F-I36-20MA-000-000 for my specific technical solution?

    • Calibration procedures may vary, but typically involve applying known pressures and adjusting the transducer's output signal to match the expected values, often using calibration equipment or software.
  7. What are the maintenance requirements for P51-50-G-F-I36-20MA-000-000 in technical solutions?

    • Regular inspection for damage, cleaning, and periodic calibration checks are common maintenance tasks to ensure the continued accuracy and reliability of the pressure transducer in technical solutions.
  8. Can P51-50-G-F-I36-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, this pressure transducer's 4-20mA output signal makes it compatible with most programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) systems for seamless integration.
  9. What is the typical lifespan of P51-50-G-F-I36-20MA-000-000 in technical solutions?

    • With proper maintenance and usage, the pressure transducer can have a long operational lifespan, often exceeding 10 years in many technical applications.
  10. Are there any special considerations when installing P51-50-G-F-I36-20MA-000-000 in technical solutions?

    • Ensuring proper sealing, mounting orientation, and protection from excessive vibration or shock are important considerations during installation to optimize the performance and longevity of the pressure transducer.