Product Overview

Category

The P51-500-A-L-I12-20MA-000-000 belongs to the category of industrial pressure sensors.

Use

It is used for measuring and monitoring pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial processes

Package

The sensor is typically packaged in a durable housing suitable for industrial environments.

Essence

The essence of the P51-500-A-L-I12-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in industrial settings.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel
  • Electrical Connection: Integral cable

Detailed Pin Configuration

The detailed pin configuration of the P51-500-A-L-I12-20MA-000-000 includes: - Pin 1: Power supply - Pin 2: Ground - Pin 3: Signal output

Functional Features

  • High precision pressure measurement
  • Compatibility with various industrial fluids
  • Long-term stability
  • Overpressure protection

Advantages

  • Reliable and accurate measurements
  • Suitable for harsh industrial environments
  • Long-term durability
  • Compatibility with standard industrial interfaces

Disadvantages

  • Limited pressure range compared to some other industrial sensors
  • Requires calibration at regular intervals

Working Principles

The P51-500-A-L-I12-20MA-000-000 operates on the principle of strain gauge technology, where the deformation of the sensor due to pressure results in a change in electrical resistance, which is then converted into a proportional 4-20 mA output signal.

Detailed Application Field Plans

The P51-500-A-L-I12-20MA-000-000 is well-suited for applications such as: - Hydraulic systems - Industrial machinery - Process control - Pressure monitoring in manufacturing processes

Detailed and Complete Alternative Models

Some alternative models to the P51-500-A-L-I12-20MA-000-000 include: - P51-100-A-L-I12-20MA-000-000 (0-100 psi range) - P51-1000-A-L-I12-20MA-000-000 (0-1000 psi range) - P51-2000-A-L-I12-20MA-000-000 (0-2000 psi range)

In conclusion, the P51-500-A-L-I12-20MA-000-000 industrial pressure sensor offers high precision, reliability, and durability for a wide range of industrial applications, making it an essential component in industrial pressure monitoring systems.

[Word count: 410]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-500-A-L-I12-20MA-000-000 v technických řešeních

  1. What is the P51-500-A-L-I12-20MA-000-000 used for?

    • The P51-500-A-L-I12-20MA-000-000 is a pressure transducer commonly used to measure and transmit pressure readings in industrial and technical applications.
  2. What is the operating range of the P51-500-A-L-I12-20MA-000-000?

    • The operating range of the P51-500-A-L-I12-20MA-000-000 is typically from 0 to 500 psi, making it suitable for a wide range of pressure measurement tasks.
  3. How does the P51-500-A-L-I12-20MA-000-000 interface with control systems?

    • The P51-500-A-L-I12-20MA-000-000 typically interfaces with control systems using a 4-20mA output signal, allowing for easy integration into various control and monitoring systems.
  4. What are the common applications of the P51-500-A-L-I12-20MA-000-000?

    • Common applications of the P51-500-A-L-I12-20MA-000-000 include hydraulic systems, pneumatic systems, industrial machinery, and process control systems.
  5. Is the P51-500-A-L-I12-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-500-A-L-I12-20MA-000-000 is often designed to withstand harsh environmental conditions, including high temperatures, humidity, and vibration.
  6. Can the P51-500-A-L-I12-20MA-000-000 be calibrated or adjusted?

    • Yes, the P51-500-A-L-I12-20MA-000-000 can often be calibrated or adjusted to ensure accurate pressure measurements based on specific requirements.
  7. What is the typical response time of the P51-500-A-L-I12-20MA-000-000?

    • The typical response time of the P51-500-A-L-I12-20MA-000-000 is fast, allowing for real-time monitoring and control of pressure changes.
  8. Does the P51-500-A-L-I12-20MA-000-000 require regular maintenance?

    • While the P51-500-A-L-I12-20MA-000-000 is designed for reliability, periodic maintenance and calibration checks are recommended to ensure accurate performance over time.
  9. Can the P51-500-A-L-I12-20MA-000-000 be integrated with digital communication protocols?

    • Yes, some versions of the P51-500-A-L-I12-20MA-000-000 support digital communication protocols such as Modbus or HART for enhanced connectivity and data transmission.
  10. What are the key considerations when selecting the P51-500-A-L-I12-20MA-000-000 for a technical solution?

    • Key considerations include the required pressure range, compatibility with control systems, environmental conditions, and any specific communication protocol needs.