Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-500-S-Z-MD-20MA-000-000

P51-500-S-Z-MD-20MA-000-000

Product Overview

Category

The P51-500-S-Z-MD-20MA-000-000 belongs to the category of precision pressure transducers.

Use

It is used for accurately measuring and transmitting pressure readings in various industrial and commercial applications.

Characteristics

  • High precision
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various media
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-500-S-Z-MD-20MA-000-000 lies in its ability to provide accurate and reliable pressure measurements in demanding environments.

Packaging/Quantity

The standard packaging includes individual units, and the quantity may vary based on customer requirements.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel
  • Electrical Connection: M12 connector

Detailed Pin Configuration

The detailed pin configuration of the P51-500-S-Z-MD-20MA-000-000 is as follows: - Pin 1: Power supply + - Pin 2: Power supply - - Pin 3: Signal output +

Functional Features

  • High accuracy and repeatability
  • Built-in temperature compensation
  • Overpressure protection
  • Easy installation and maintenance

Advantages and Disadvantages

Advantages

  • Precise and reliable pressure measurements
  • Suitable for harsh environments
  • Long-term stability
  • Easy integration into existing systems

Disadvantages

  • Higher initial cost compared to standard pressure sensors
  • Requires periodic calibration and maintenance

Working Principles

The P51-500-S-Z-MD-20MA-000-000 operates on the principle of strain gauge technology, where the applied pressure causes deformation in the sensing element, resulting in a change in electrical resistance. This change is then converted into a proportional 4-20 mA output signal.

Detailed Application Field Plans

The P51-500-S-Z-MD-20MA-000-000 is well-suited for various applications, including: - Industrial automation - Hydraulic systems - Process control - Aerospace and defense - Automotive testing

Detailed and Complete Alternative Models

Some alternative models to the P51-500-S-Z-MD-20MA-000-000 include: - P51-100-S-N-I12-5V-000-000 - P51-1000-A-S-I36-10V-000-000 - P51-2500-S-N-I36-5V-000-000

In conclusion, the P51-500-S-Z-MD-20MA-000-000 precision pressure transducer offers high accuracy, reliability, and robustness, making it an ideal choice for demanding industrial and commercial applications.

[Word count: 398]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-500-S-Z-MD-20MA-000-000 v technických řešeních

  1. What is the P51-500-S-Z-MD-20MA-000-000 used for?

    • The P51-500-S-Z-MD-20MA-000-000 is a pressure transducer commonly used to measure and monitor pressure in various technical solutions.
  2. What is the operating range of the P51-500-S-Z-MD-20MA-000-000?

    • The operating range of the P51-500-S-Z-MD-20MA-000-000 is typically from 0 to 500 psi.
  3. What are the output options for the P51-500-S-Z-MD-20MA-000-000?

    • The P51-500-S-Z-MD-20MA-000-000 typically provides a 4-20mA output signal, making it compatible with many control systems.
  4. Is the P51-500-S-Z-MD-20MA-000-000 suitable for use in harsh environments?

    • Yes, the P51-500-S-Z-MD-20MA-000-000 is often designed to withstand harsh industrial environments and is available in various ruggedized versions.
  5. Can the P51-500-S-Z-MD-20MA-000-000 be used for liquid as well as gas pressure measurement?

    • Yes, the P51-500-S-Z-MD-20MA-000-000 can be used for measuring both liquid and gas pressures, depending on the specific application requirements.
  6. What is the accuracy of the P51-500-S-Z-MD-20MA-000-000?

    • The accuracy of the P51-500-S-Z-MD-20MA-000-000 is typically within a certain percentage of the full scale, such as +/- 0.5% FS.
  7. How is the P51-500-S-Z-MD-20MA-000-000 installed and calibrated?

    • The P51-500-S-Z-MD-20MA-000-000 is usually installed using standard NPT fittings and can be calibrated using appropriate tools and procedures provided by the manufacturer.
  8. What are the common applications for the P51-500-S-Z-MD-20MA-000-000?

    • Common applications for the P51-500-S-Z-MD-20MA-000-000 include hydraulic systems, industrial machinery, HVAC systems, and process control.
  9. Is the P51-500-S-Z-MD-20MA-000-000 compatible with digital communication protocols?

    • Some versions of the P51-500-S-Z-MD-20MA-000-000 may offer compatibility with digital communication protocols such as Modbus or HART.
  10. Are there any special considerations for maintenance of the P51-500-S-Z-MD-20MA-000-000?

    • Regular calibration checks and ensuring proper electrical connections are important for maintaining the performance of the P51-500-S-Z-MD-20MA-000-000.