Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
P51-750-S-B-D-20MA-000-000

P51-750-S-B-D-20MA-000-000

Product Overview

Category

The P51-750-S-B-D-20MA-000-000 belongs to the category of pressure sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Wide operating temperature range
  • Compact size
  • Robust construction

Package

The sensor is typically packaged in a protective housing with appropriate connectors for easy installation.

Essence

The essence of the P51-750-S-B-D-20MA-000-000 lies in its ability to provide precise pressure measurements in challenging environments.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-750 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 125°C
  • Accuracy: ±0.5% full scale
  • Supply Voltage: 10-30 VDC

Detailed Pin Configuration

The detailed pin configuration of the P51-750-S-B-D-20MA-000-000 is as follows: 1. Power supply (+) 2. Power supply (-) 3. Signal output 4. Not connected

Functional Features

  • High precision pressure measurement
  • Compatibility with various media
  • Long-term stability
  • Overpressure protection

Advantages

  • Reliable and accurate performance
  • Suitable for harsh environments
  • Low power consumption
  • Easy integration into existing systems

Disadvantages

  • Limited pressure range compared to some other models
  • May require additional protection in extremely corrosive environments

Working Principles

The P51-750-S-B-D-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, resulting in a proportional change in electrical resistance. This change is then converted into a standardized output signal.

Detailed Application Field Plans

The P51-750-S-B-D-20MA-000-000 is widely used in: - Hydraulic systems - Industrial machinery - Process control - Automotive applications - Aerospace industry

Detailed and Complete Alternative Models

Some alternative models to the P51-750-S-B-D-20MA-000-000 include: - P51-500-S-B-D-20MA-000-000 - P51-1000-S-B-D-20MA-000-000 - P51-750-S-B-D-10V-000-000

In conclusion, the P51-750-S-B-D-20MA-000-000 pressure sensor offers high precision and reliability, making it an ideal choice for various industrial applications. Its robust construction and compatibility with different media make it a versatile solution for pressure measurement needs.

[Word count: 398]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací P51-750-S-B-D-20MA-000-000 v technických řešeních

  1. What is the application of P51-750-S-B-D-20MA-000-000?

    • The P51-750-S-B-D-20MA-000-000 is a pressure transducer commonly used in industrial and technical applications to measure and monitor pressure in various systems.
  2. What are the typical operating conditions for P51-750-S-B-D-20MA-000-000?

    • The P51-750-S-B-D-20MA-000-000 is designed to operate within a specified temperature range and pressure limits, making it suitable for a wide range of industrial and technical environments.
  3. How does P51-750-S-B-D-20MA-000-000 interface with control systems?

    • This transducer typically provides a 4-20mA output signal that can be easily interfaced with control systems, PLCs, and other monitoring devices.
  4. Can P51-750-S-B-D-20MA-000-000 be used in hazardous environments?

    • Yes, the P51-750-S-B-D-20MA-000-000 is available in intrinsically safe versions, allowing its use in hazardous or explosive environments.
  5. What are the calibration requirements for P51-750-S-B-D-20MA-000-000?

    • Calibration may be required periodically to ensure accurate pressure measurements, and this can typically be performed using standard calibration equipment.
  6. Is P51-750-S-B-D-20MA-000-000 suitable for high-pressure applications?

    • Yes, this transducer is often used in high-pressure applications such as hydraulic systems, process control, and industrial machinery.
  7. What are the common failure modes of P51-750-S-B-D-20MA-000-000?

    • Common failure modes may include sensor drift, electrical connection issues, or damage due to excessive pressure or environmental factors.
  8. Can P51-750-S-B-D-20MA-000-000 be integrated with digital communication protocols?

    • Yes, some models of this transducer support digital communication protocols such as Modbus or HART for enhanced connectivity and data transmission.
  9. What are the recommended installation practices for P51-750-S-B-D-20MA-000-000?

    • Proper mounting, sealing, and electrical connections are crucial for optimal performance, and following manufacturer guidelines for installation is recommended.
  10. Are there any special considerations for maintenance of P51-750-S-B-D-20MA-000-000?

    • Regular inspection for signs of wear, cleaning of pressure ports, and adherence to recommended maintenance intervals can help ensure the longevity and accuracy of the transducer.