Obrázek může být reprezentace.
Viz Specifikace pro podrobnosti o produktu.
W58-XB1A4A-1

W58-XB1A4A-1 English Editing Encyclopedia Entry

Product Overview

The W58-XB1A4A-1 belongs to the category of thermal circuit breakers and is designed for use in various electrical applications. Its characteristics include a compact design, high reliability, and the ability to protect electrical circuits from overcurrent conditions. The package includes the W58-XB1A4A-1 unit itself, along with essential documentation and installation instructions. The essence of this product lies in its ability to provide efficient and reliable protection for electrical systems. It is typically packaged individually and is available in varying quantities based on the specific requirements of the user.

Specifications

  • Voltage Rating: 250VAC, 50VDC
  • Current Rating: 3A
  • Trip Time: 5 seconds at 200% of rated current
  • Operating Temperature: -10°C to 60°C
  • Reset Method: Manual reset

Detailed Pin Configuration

The W58-XB1A4A-1 features a standard pin configuration with clearly labeled terminals for easy installation and connection to the electrical circuit. The detailed pin configuration can be found in the product datasheet or user manual.

Functional Features

  • Overcurrent Protection: The W58-XB1A4A-1 is designed to trip and interrupt the circuit in the event of an overcurrent condition, effectively protecting the connected equipment.
  • Manual Reset: The manual reset feature allows users to easily restore the circuit after a trip, providing convenience and control.

Advantages and Disadvantages

Advantages

  • Compact Design: The compact size of the W58-XB1A4A-1 makes it suitable for installations where space is limited.
  • High Reliability: This thermal circuit breaker offers high reliability and consistent performance in protecting electrical circuits.

Disadvantages

  • Limited Current Rating: The 3A current rating may not be suitable for high-power applications, requiring users to consider alternative models for such scenarios.

Working Principles

The W58-XB1A4A-1 operates based on the principle of thermal-magnetic protection. When an overcurrent condition occurs, the internal bimetallic strip heats up, causing it to bend and trip the breaker, thereby interrupting the circuit and preventing damage to the connected equipment.

Detailed Application Field Plans

The W58-XB1A4A-1 is commonly used in various electrical applications, including but not limited to: - Control panels - Power distribution units - Industrial machinery - Automotive electronics

Detailed and Complete Alternative Models

For applications requiring different specifications or ratings, alternative models to consider include: - W58-XB1A4A-2: 5A current rating - W58-XB1A4A-3: 7A current rating - W58-XB1A4A-4: 10A current rating

In conclusion, the W58-XB1A4A-1 thermal circuit breaker offers reliable overcurrent protection in a compact and efficient package, making it suitable for a wide range of electrical applications.

[Word count: 398]

Seznam 10 běžných otázek a odpovědí souvisejících s aplikací W58-XB1A4A-1 v technických řešeních

  1. What is the W58-XB1A4A-1?

    • The W58-XB1A4A-1 is a thermal circuit breaker designed to protect electrical equipment from overcurrent and short circuit conditions.
  2. What is the voltage and current rating of the W58-XB1A4A-1?

    • The W58-XB1A4A-1 has a voltage rating of 250VAC and a current rating of 10A.
  3. How does the W58-XB1A4A-1 function?

    • The W58-XB1A4A-1 functions by automatically interrupting the flow of current when it exceeds the rated capacity, thereby protecting the circuit from damage.
  4. What are the typical applications of the W58-XB1A4A-1?

    • The W58-XB1A4A-1 is commonly used in power supplies, industrial equipment, appliances, and automotive systems to provide overcurrent protection.
  5. Is the W58-XB1A4A-1 suitable for use in harsh environments?

    • Yes, the W58-XB1A4A-1 is designed to withstand harsh environmental conditions and is suitable for use in demanding applications.
  6. Does the W58-XB1A4A-1 require regular maintenance?

    • No, the W58-XB1A4A-1 is a maintenance-free device and does not require regular servicing under normal operating conditions.
  7. Can the W58-XB1A4A-1 be reset after tripping?

    • Yes, the W58-XB1A4A-1 can be manually reset after tripping, allowing for easy restoration of the circuit.
  8. What are the safety features of the W58-XB1A4A-1?

    • The W58-XB1A4A-1 includes safety features such as trip-free operation and a robust construction to ensure reliable protection.
  9. Are there any special installation requirements for the W58-XB1A4A-1?

    • The W58-XB1A4A-1 can be easily installed using standard mounting procedures and does not have any special installation requirements.
  10. Where can I find detailed technical specifications for the W58-XB1A4A-1?

    • Detailed technical specifications for the W58-XB1A4A-1 can be found in the product datasheet provided by the manufacturer or supplier.